KSD250 - Click to enlarge

Solar Tunnel Drier KSD 250                            - Click here for Brochure

  • Hygienic drying.
  • No color degradation due to UV rays.
  • Uninterrupted year round operations with bio gas, LPG or electric backup.
  • Lower running costs hence higher saving.
DESCRIPTION OF DRIER

Casing (Drying chamber) : The drying chamber is made of double walled fabricated casing with 50 mm PUF insulation. Inner wall of casing is made of SS 304 and outer wall with M.S. painted finish.

Size of chamber : 4000 L x 1500 W x 2900 H

Trays : Perforated SS 304 sheets or SS wire mesh – size 600 x 900 x 25
Quantity - 108 Nos (27 Nos in each trolley with 4 trolleys.)

Heating : Hot water from solar calorifier tank is circulated inside the chamber into two heat exchangers made of SS 304 finned tubes. The water from the calorifier tank will also be heated by LPG as a back up arrangement.

Air heater Collectors : Each air collector is of size 2 M x 1 M and 3 collectors can be arranged in parallel / series configuration as per availability of space. This hot air is taken as inlet air into the chamber.

Air Circulation : Two Axial flow fans of 6000 cfm/hr capacity provides the air circulation inside the chamber.

Electric Control System : The blower will have on / off control, the Gas backup heaters can controlled automatically by a temperature controller. The temperature can be measured in two or three points in the tunnel. The humidity inside the chamber is read in a digital controller that controls the exhaust fans.

Time of drying and output : The time of drying and specific weight of each product varies considerably. For eg: 2.5 to 3 Kg of material can be loaded in each tray and therefore capacity of the drier can be 250 to 300kg on a wet basis.


SPECIFICATION OF KSD50 TUNNEL DRIER

1

Size of the chamber

Length - 4000 mm, Width - 1500 mm, Height - 2900 mm

2

Maximum temperature

70 deg. C

3

Heating

Hot water generated from solar collectors circulated into the casing through heat exchangers. Back LPG/ Bio gas heaters provided.

4

Blowers

2Nos of 2 HP each

5

Power Supply

240V Single Phase / 440 V 3 Phase.

6

Number of trolleys

4 Nos.

7

Charge Per Tray

2.5 Kg to 3 Kg.

8

Tray material

SS 304

9

Tray size

600 x 900 x 25

10

Solar Collectors

400 Vaccum tubes of 47 x 1400 mm arranged in 8 collectors.

11
Gas Backup 6 Nos of YellowStone Gas geysers connected to calorifier tank by a 0.5 HP pump
12
Control Panel Controls for hot water circulation pump, back up gas geysers, Humidity controls for exhaust fans.
13
Air Heating Panels 3 Nos of 2m x 1m hot air collectors for pre-heating inlet air.

    For current price please and other enquires please email [email protected]

   Click here for - KSD50  KSD500  KSD1000                                        back to Products>
Picture
 Kraftwork Solar Pvt Ltd, established in 1993, is the pioneer of Solar water heating technology in  Kerala.
  • 29/2862. Adithya, Near Gandhi Sq. Poonithura, Kochi 682 038.
  • Phone: 7994615485
  •  [email protected] ​

Follow Us for latest Updates.

USEFULL LINKS

PRIVACY POLICY
TERMS AND CONDITIONS

SHIPPING AND RETURN
Solar in Kerala
  • HOME
  • RESIDENTIAL
    • ROOFTOP SOLAR
    • SOLAR WATER HEATERS
  • COMMERCIAL
    • SOLAR WATER HEATERS
    • SOLAR DRIER
    • ROOFTOP SOLAR
    • HEAT PUMP
  • ABOUT US
  • CONTACT